Instruments
Showing 151–165 of 174 results
-
ING1114S
- Rotating slide-wheel reference table for use with whirling hygrometers
- Set the pointers to the recorded wet bulb and dry bulb temperature readings and read the dew point temperature
- Calculate the relative humidity %
- Sturdy plastic construction
- Calculation Accuracy ± 1% - compared to Standard Tables
- Includes °C and °F converter
ING1114S- Rotating slide-wheel reference table for use with whirling hygrometers
- Set the pointers to the recorded wet bulb and dry bulb temperature readings and read the dew point temperature
- Calculate the relative humidity %
- Sturdy plastic construction
- Calculation Accuracy ± 1% - compared to Standard Tables
- Includes °C and °F converter
-
WHEL999147TSP-3 DIGITAL ALMEN GAUGE
- Used for measuring almen strip shot peening intensity
- Easy to use
- Has magnetic grip to hold almen strips in place
- Meets SAE and aerospace specifications including SAE J 442 and AMS 2430
WHEL999147TSP-3 DIGITAL ALMEN GAUGE- Used for measuring almen strip shot peening intensity
- Easy to use
- Has magnetic grip to hold almen strips in place
- Meets SAE and aerospace specifications including SAE J 442 and AMS 2430
-
FLXUFT01Helideck micro GripTester
- For use on Helipad, Heli deck, Ship deck
- Test the friction resistance of surface
- Adopted as the standard in the industry across the globe. The micro GripTester complies with UK CAA CAP437.
FLXUFT01Helideck micro GripTester- For use on Helipad, Heli deck, Ship deck
- Test the friction resistance of surface
- Adopted as the standard in the industry across the globe. The micro GripTester complies with UK CAA CAP437.
-
INDPT30KPT Holiday Detector Kit 0-30kV, c/w band brush probe
- For use with coatings up to 8,000 microns.
- Resolution of 0.1kV
INDPT30KPT Holiday Detector Kit 0-30kV, c/w band brush probe- For use with coatings up to 8,000 microns.
- Resolution of 0.1kV
-
INCASEBOProtect your valuable instruments with this new robust carry case.
- Suitable for small hand held devices (e.g. DeFelsko Positector range)
- Includes pick and pluck foam for secure storage
- Case internal dimensions: 235mm L x 181mm W x 105mm D
- Press & pull latches
- Pad-lockable hasps
INCASEBOProtect your valuable instruments with this new robust carry case.- Suitable for small hand held devices (e.g. DeFelsko Positector range)
- Includes pick and pluck foam for secure storage
- Case internal dimensions: 235mm L x 181mm W x 105mm D
- Press & pull latches
- Pad-lockable hasps
-
INE130BRESLE1
- Refill kit with 50 bresle patches
- Used to measure total salts (Chlorides)
- High adhesion bresle patches version
- Measurement range: 20 ppm to 5000 ppm
- Used in accordance with ISO8502-6, AS1627-4 Standards
INE130BRESLE1- Refill kit with 50 bresle patches
- Used to measure total salts (Chlorides)
- High adhesion bresle patches version
- Measurement range: 20 ppm to 5000 ppm
- Used in accordance with ISO8502-6, AS1627-4 Standards
-
BlastOne offers all instruments and accessories from the DeFelsko product line.
These rolling springs are the electrodes suited for DeFelsko® high voltage holiday detection on steel pipes, and additional information is as follows:
- Multiple sizes available, 4-36"
- Each electrode includes two pre-installed spring couplers. Replacement couplers are available in packs of 2.
- Requires one Spring Connector to connect either DeFelsko or SPY spring electrodes to PosiTest HHD (sold separately).
- Sold Individually
-
INE130SC2
- Used as part of the SCAT Kit For measuring chloride ion content in the titration solution
- Replacement Chloride Ion Titration Strips
- Come in a Bottle of 40
INE130SC2- Used as part of the SCAT Kit For measuring chloride ion content in the titration solution
- Replacement Chloride Ion Titration Strips
- Come in a Bottle of 40
-
INE130SC3
- Pack: 100
- For measuring the Ferrous ion content In the titration solution
INE130SC3- Pack: 100
- For measuring the Ferrous ion content In the titration solution
-
INE130SC1
- For analysis of chloride ions, ferrous ions and pH level
- Chloride Ion Detection Threshold: approx 40 ppm
- Ferrous Ion Detection Threshold: approx 3 ppm
- pH measurement range: 4 to 9 verified by color scale
- Complete kit supplied with graduated cylinder, beakers, tweezers, water demineralizer cartridge, cotton balls, chloride ion titration strips, ferrous ion titration strips, ruler, instructions and hard cover carry-case
- Surface Contamination Analysis Test (SCAT) Kit
- 'Swab method' used in accordance with AS1627-1, AS3894-6 Standard
INE130SC1- For analysis of chloride ions, ferrous ions and pH level
- Chloride Ion Detection Threshold: approx 40 ppm
- Ferrous Ion Detection Threshold: approx 3 ppm
- pH measurement range: 4 to 9 verified by color scale
- Complete kit supplied with graduated cylinder, beakers, tweezers, water demineralizer cartridge, cotton balls, chloride ion titration strips, ferrous ion titration strips, ruler, instructions and hard cover carry-case
- Surface Contamination Analysis Test (SCAT) Kit
- 'Swab method' used in accordance with AS1627-1, AS3894-6 Standard
-
ING116C1Whirling Hygrometer for measuring dry bulb and wet bulb air temperatures. Allows for the calculation of Humidity and Dew Point.
- Folding handle for compact storage
- Replaceable thermometers
- Measurement range +30°F to +110°F (0°C to +43°C)
- Calculated relative humidity accuracy ± 5% RH
- Calculated dewpoint accuracy ± 5°F (3°C)
- Optional pre-delivery Test Certificate – order separately
- Bacharach sling hygrometers also available in °C or °F (not pictured)
ING116C1Whirling Hygrometer for measuring dry bulb and wet bulb air temperatures. Allows for the calculation of Humidity and Dew Point.- Folding handle for compact storage
- Replaceable thermometers
- Measurement range +30°F to +110°F (0°C to +43°C)
- Calculated relative humidity accuracy ± 5% RH
- Calculated dewpoint accuracy ± 5°F (3°C)
- Optional pre-delivery Test Certificate – order separately
- Bacharach sling hygrometers also available in °C or °F (not pictured)
-
INEBSPG
- Visual representation of rust and coating preparation grades on steel substrates
- Similar to SSPC-VIS 1 Visual Standards and Reference Photographs
- Handy flip-top, wire bound, reference book
- Provides a visual comparison with SSPC standards. Full color photographs. Wipe-clean gloss pages. Flip top wire binding. Supplied in a protective pouch.
- Not a certified visual standard - use as a guide
INEBSPG- Visual representation of rust and coating preparation grades on steel substrates
- Similar to SSPC-VIS 1 Visual Standards and Reference Photographs
- Handy flip-top, wire bound, reference book
- Provides a visual comparison with SSPC standards. Full color photographs. Wipe-clean gloss pages. Flip top wire binding. Supplied in a protective pouch.
- Not a certified visual standard - use as a guide
-
INE1124MThe "Testex Surface Profile Dial Thickness Gauge Microns" (SKU: INE1124M) offers accurate measurement of surface profiles on Testex replica tape. Compliant with ISO8503-5, AS3894-5, and AS1627-4 standards, this gauge kit ensures precision in every paint inspection.
- Used to measure the maximum surface profile produces on the Testex replica tape
-
Kit includes
- Dial thickness gage for microns
- Protective storage case
- Used in accordance with ISO8503-5, AS3894-5 and AS1627-4 Standards
INE1124MThe "Testex Surface Profile Dial Thickness Gauge Microns" (SKU: INE1124M) offers accurate measurement of surface profiles on Testex replica tape. Compliant with ISO8503-5, AS3894-5, and AS1627-4 standards, this gauge kit ensures precision in every paint inspection.- Used to measure the maximum surface profile produces on the Testex replica tape
-
Kit includes
- Dial thickness gage for microns
- Protective storage case
- Used in accordance with ISO8503-5, AS3894-5 and AS1627-4 Standards
-
WHEL999314VLP-24 MagnaValve - Shot Control Valve, 200-1000 Lbs flow rate, no sensor, 2.5" high 24 VdcWHEL999314VLP-24 MagnaValve - Shot Control Valve, 200-1000 Lbs flow rate, no sensor, 2.5" high 24 Vdc